This course will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu V-Series heat pump system. It includes: selecting proper equipment location and will teach how to read and utilize the “Design Simulator Report” for proper pipe size and routing. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting, how to address indoor units and how to combine multiple OD units in one refrigerant circuit are included. The class will cover how to check the system setup to be ready for a system commissioning.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.
This training will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu J-Series system. It includes: selecting proper equipment location. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting and how to address indoor units is also included. The class will cover basic function codes after installation to qualify the systems set-up for startup.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.
This training will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu J-Series system. It includes: selecting proper equipment location. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting and how to address indoor units is also included. The class will cover basic function codes after installation to qualify the systems set-up for startup.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.
This training will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu J-Series system. It includes: selecting proper equipment location. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting and how to address indoor units is also included. The class will cover basic function codes after installation to qualify the systems set-up for startup.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.
This is a Fujitsu Live Web Training course discussing Halcyon Mini-Split Top 10 Installation and Maintenance issues seen in the field, either at startup or after installation. This course is designed to go 1 1/2 to 2 hours maximum, including quiz.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your email confirmation from APR Supply Co.
This training is intended to provide an experienced installer the ability to understand the setup and startup of a “standard” installation in a cold climate. It is based on use of a factory accessory electric auxiliary heat kit. It includes function settings and custom setup to match your applications and the needs of your customers.
Click the button below to register.
NOTE: This webinar is hosted directly by Fujitsu so you will not receive your email confirmation from APR Supply Co. There are multiple sessions available. Please choose the time that works best for you.
Fujitsu Infinite Comfort Series Multi Position Air Handler 3 hour Fujitsu Live Web Training. The session provides Product, Application, and Installation training for this amazing Mini-Split Heat Pump product!
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your email confirmation from APR Supply Co.
This course will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu V-Series heat pump system. It includes: selecting proper equipment location and will teach how to read and utilize the “Design Simulator Report” for proper pipe size and routing. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting, how to address indoor units and how to combine multiple OD units in one refrigerant circuit are included. The class will cover how to check the system setup to be ready for a system commissioning.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.
This course will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu V-Series heat pump system. It includes: selecting proper equipment location and will teach how to read and utilize the “Design Simulator Report” for proper pipe size and routing. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting, how to address indoor units and how to combine multiple OD units in one refrigerant circuit are included. The class will cover how to check the system setup to be ready for a system commissioning.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.
This course will equip the installer with the knowledge to rough-in, install, pipe and wire a Fujitsu V-Series heat pump system. It includes: selecting proper equipment location and will teach how to read and utilize the “Design Simulator Report” for proper pipe size and routing. Key examples provide knowledge for use of separation tubes or pipe headers. Communication wiring, address setting, how to address indoor units and how to combine multiple OD units in one refrigerant circuit are included. The class will cover how to check the system setup to be ready for a system commissioning.
Click the button below to register.
This training is hosted directly by Fujitsu, so you will not receive your
email confirmation from APR Supply Co.